A technology of cinacalcet hydrochloride and enantiomer, which is applied in the field of high performance liquid chromatography, can solve the problems of complicated operation, high cost, long analysis time, etc., achieve high-purity preparation, ensure stability, and improve symmetry sexual effect
- Summary
- Abstract
- Description
- Claims
- Application Information
AI Technical Summary
Problems solved by technology
Method used
Image
Examples
Embodiment 1
[0044] Instruments and Conditions
[0045] Thermo Fisher U3000 High Performance Liquid Chromatograph;
[0046] Chromatographic column: OJ-H (250mm×4.6mm, 5μm) cellulose-tris(4-methylbenzoate) chiral column;
[0047] Mobile phase volume ratio: n-hexane: absolute ethanol: ethanolamine=70:30:0.1;
[0048] Detection wavelength: 222nm;
[0049] Column temperature: 25°C;
[0050] Flow rate: 0.5ml / min;
[0051] Injection volume: 20 μl.
[0052] Experimental procedure
[0053] R-cinacalcet hydrochloride: Accurately weigh an appropriate amount of R-cinacalcet hydrochloride reference substance, dissolve it with the mobile phase, dilute it with the mobile phase to a solution containing about 2 μg per 1 ml, accurately measure 20 μl and inject it into the chromatograph, record Chromatogram, the chromatogram of R-cinacalcet hydrochloride see figure 1 , the peak is around 9.9min.
[0054] S-cinacalcet hydrochloride solution: accurately weigh an appropriate amount of S-cinacalcet hydr...
Embodiment 2
[0057] Instruments and Conditions
[0058] Thermo Fisher U3000 High Performance Liquid Chromatograph;
[0059] Chromatographic column: OJ-H (250mm×4.6mm, 5μm) cellulose-tris(4-methylbenzoate) chiral column;
[0060] Mobile phase volume ratio: n-hexane: absolute ethanol: ethanolamine = 65: 35: 0.1;
[0061] Detection wavelength: 222nm;
[0062] Column temperature: 25°C;
[0063] Flow rate: 0.5ml / min;
[0064] Injection volume: 20 μl.
[0065] Experimental procedure
[0066] Take an appropriate amount of R-cinnacalcet hydrochloride sample and S-cinnacalcet hydrochloride (or racemate) respectively, dissolve and quantitatively dilute with mobile phase to make about R-cinnacalcet hydrochloride and S - Each 10 μg system suitability solution of cinacalcet hydrochloride, accurately measure 20 μl, inject liquid chromatograph, record the chromatogram, see the chromatogram of system suitability solution Figure 4 , the No. 1 peak in the figure is S-cinnacalcet hydrochloride, the p...
Embodiment 3
[0068] Instruments and Conditions
[0069] Thermo Fisher U3000 High Performance Liquid Chromatograph;
[0070] Chromatographic column: OJ-H (250mm×4.6mm, 5μm) cellulose-tris(4-methylbenzoate) chiral column;
[0071] Mobile phase volume ratio: n-hexane: absolute ethanol: ethanolamine=75:25:0.1;
[0072] Detection wavelength: 222nm;
[0073] Column temperature: 25°C;
[0074] Flow rate: 0.5ml / min;
[0075] Injection volume: 20 μl.
[0076] Experimental procedure
[0077] Take an appropriate amount of R-cinnacalcet hydrochloride sample and S-cinnacalcet hydrochloride (or racemate) respectively, dissolve and quantitatively dilute with mobile phase to make about R-cinnacalcet hydrochloride and S - Each 10 μg system suitability solution of cinacalcet hydrochloride, accurately measure 20 μl, inject liquid chromatograph, record the chromatogram, see the chromatogram of system suitability solution Figure 5 , peak No. 1 in the figure is S-cinnacalcet hydrochloride, which elutes ...
PUM
Property | Measurement | Unit |
---|---|---|
wavelength | aaaaa | aaaaa |
separation | aaaaa | aaaaa |
Abstract
Description
Claims
Application Information
- R&D Engineer
- R&D Manager
- IP Professional
- Industry Leading Data Capabilities
- Powerful AI technology
- Patent DNA Extraction
Browse by: Latest US Patents, China's latest patents, Technical Efficacy Thesaurus, Application Domain, Technology Topic, Popular Technical Reports.
© 2024 PatSnap. All rights reserved.Legal|Privacy policy|Modern Slavery Act Transparency Statement|Sitemap|About US| Contact US: help@patsnap.com