Method for concurrent measurement of p-phenylenediamine, o-phenylenediamine, hydroquinone and resorcinol in oxygenize type hair dyes agent
A technology of o-phenylenediamine and resorcinol, which is applied to the simultaneous determination of four dyes of resorcinol, o-phenylenediamine and p-, oxidative hair dyes, can solve the problem that the four dyes cannot be detected at the same time, Problems such as high analysis cost and high detection cost achieve the effect of low detection limit, high analysis cost and time saving
- Summary
- Abstract
- Description
- Claims
- Application Information
AI Technical Summary
Problems solved by technology
Method used
Image
Examples
Embodiment 1
[0036] The detection of four kinds of oxidized dyes in the hair dye of embodiment 1:
[0037] Reagents and samples
[0038] Anhydrous sodium sulfite (analytical grade), ethyl acetate (HPLC), o-phenylenediamine, p-phenylenediamine, hydroquinone, resorcinol standard: purity ≥ 99%;
[0039] Instruments and Equipment
[0040] Gas chromatograph Agilent 6890N (FID), chromatographic column J&W 123-0732 DB-170130m*0.32mm*0.25μm, ultrasonic cleaner, centrifuge, 0.45μm organic microporous membrane, 1.0μL micro-sampler
[0041] method:
[0042] Chromatographic conditions
[0043] Start the chromatographic instrument and make necessary adjustments to achieve the best working conditions of the instrument. The chromatographic conditions are selected according to specific conditions. The reference conditions are:
[0044] (1) Carrier gas nitrogen flow rate: 1.0mL / min; hydrogen flow rate: 30mL / min; air flow rate: 350mL / min.
[0045] (2) Inlet temperature: 250°C
[0046] (3) Injection mo...
Embodiment 2
[0066] The precision and recovery rate investigation of embodiment 2 detection method
[0067] Method precision
[0068] Take 0.2 μL of 200 and 1000 μg / mL standard solutions of p-phenylenediamine, o-phenylenediamine, hydroquinone, and resorcinol for analysis, repeat 7 times, and calculate the relative standard deviation (RSD). The height of the four compounds The RSDs of the two concentrations are 1.7%-4.6%, the results are shown in the table
[0069] Table 1 Precision test results (n=7)
[0070]
[0071] The recovery rate investigation of the method:
[0072] Take L'Oreal cream and liquid hair dyes, measure the samples, add 1000μg / mL standard solution respectively, and pretreat them according to the pretreatment steps, analyze according to the chromatographic analysis conditions, inject samples in parallel 3 times, and measure The sample recoveries ranged from 87.5% to 107.7%, and the results are shown in Table 2.
[0073] Table 2 Hair dye recovery test results (n=3) ...
PUM
Abstract
Description
Claims
Application Information
- R&D Engineer
- R&D Manager
- IP Professional
- Industry Leading Data Capabilities
- Powerful AI technology
- Patent DNA Extraction
Browse by: Latest US Patents, China's latest patents, Technical Efficacy Thesaurus, Application Domain, Technology Topic, Popular Technical Reports.
© 2024 PatSnap. All rights reserved.Legal|Privacy policy|Modern Slavery Act Transparency Statement|Sitemap|About US| Contact US: help@patsnap.com